Be quick, the score pages change fast, For actual Training schools try FireTech.Com Deep training Method- Or- NTC Practice Test Method. According to the State Fire Marshal regulations, who is responsible for determining that the number and placement of loudspeakers, as part of protective signaling systems meet the requirements of applicable standards? A. In a proprietary system, when the runner is not in attendance at the central supervising station, the runner shall establish two-way communication with the central station at intervals not exceeding ----- minutes. A coded FA system must automatically transmit at least ----- rounds of the devices associated number. A non-restorable initiating device is a device whose sensing element is designed to be destroyed by the process of detecting a fire. T/F? The end of 1970 the identification of asbestos on a person’s health was confirmed by the OSH Act (Markowi... Before conducting the experiment, switch on the "MAINS" the Control Unit of Soxtec® Avanti System 2055. Smoke alarms and smoke detectors installed in household FA systems are subject to specific location requirements, one of which states that these detectors or smoke alarms shall not be installed within ----- horizontally from the tip of the blade of a ceiling fan. The off-normal signal shall be obtained either during the ----- revolutions of a hand wheel or when the stem of the valve has moved 1/5th of the distance from its normal position. Each DART shall automatically initiate and complete a test transmission sequence to its associated DARR at least once every -----. If circuits are protected in conduit, monitoring for integrity shall be required for the wiring run between control panel enclosures located _____. Questions focus heavily on notification, detection, obstructions, spacing, circuits, survivability, acoustic levels /loss, wire resistance / size, and voltage drop. Level I 29 CFR 1910 29 CFR 1926 FP HB V-1 FP … How many supervisory devices can be installed on one zone or initiating device circuit (IDC)? Oklahoma Burglar Fire Alarm license test study material package! fdny. A switch for silencing the trouble signal sounding appliance shall be permitted if it transfers the trouble indication to a lamp or other acceptable visible indicator adjacent to the switch. Public FA reporting systems shall in their entirety, be subject to ----- upon completion of the system installation. Exposed water storage containers shall be supervised to obtain two separate and distinct signals. A ---- is a municipal FA box that can also be operated by remote means. In areas that are not continuously occupied and are not fully sprinklered, automatic smoke detection, shall be provided at the location of each FA control unit as well as each ----- to provide notification of a fire at that location. Smoke detectors in rooms with ceiling slopes greater than ----- rise per ----- horizontally shall be located at the high side of the room. unique and distinctive enough to awaken a sleeping person. The owner of the system or his representatives are responsible to see that this agreement is provide. Only a ULC listed company . (3). Inspection and Testing of Fire Alarm Systems This certification program is for engineering technicians engaged in the performance, documentation, planning, and coordination of periodic inspection and testing of existing fire alarm systems and their components. If a guard fails to actuate a tour station as scheduled, the system shall automatically transmit a delinquency signal within ----- minutes after the predetermined actuation time. 126 terms. Circuits between the protected premises and the supervising or subsidiary station, that are essential to the actuation or operation of devices initiating a signal indicative of fire, shall be so arranged that the occurrence of a ----- or single ground will not prevent transmission of an alarm. Wherever a FA system is installed in a building pursuant to the State Fire Marshal regulation or local ordinance there must be a satisfactory ----- for the ----- of the system between the building owner and firm. Where would you find the standards that the certificates of registration exams given by the state fire marshal are based on? In general the system shall test free of grounds 2. Our practice exam software has sold more copies than any other. Shunt systems shall be ----- with respect to any remote electrical tripping or actuating devices. An actual test of the system is required once every 6 months. The state fire marshal may for cause, revoke or suspend a license or certificate of registration.